stranica pogledana 1207 puta artikl unesen: 20.01.2007 zadnja izmjena: 08.04.2011 VAH110proizvođač: CruzPro
All constants and calibrations are pre-set during manufacture but you may alter these settings to suit your particular needs. Calibrations can be altered using the front-panel switches for: Battery voltage (for each battery separately), battery current, charge efficiency, Peukert's exponent, battery bank capacity (in amp-hours), low and high voltage alarms and low amp hours remaining alarm value. Two auto-zero functions ( a one minute and/or a 24 hour measurement) are easily initiated from the front panel to zero the ammmeter for maximum long term accuracy. With a press of the button you can display three different battery voltages (9.50 to 33.00 VDC each in hundreths of a volt), current being delivered to or draining from the main house bank (-450 to +450 Amps, in tenths of an amp below 20.0 amps), the number of amp-hours remaining in the house bank (0 to 3000 Amp-Hours) or the percentage charge remaining in the house bank (0 to 100%). High volts, Low volts and Low Amp-Hours Remaining alarms can be independently set using the front panel switches and all alarms can be turned ON/OFF simultaneously with the press of a single key. The VAH110 draws only 0.035 amps and is designed to be left on continuously. 5 levels of backlight (including OFF) can be selected from the front panel and is saved to non-volatile memory. An external backlight on/off control is provided to switch on backlights to multiple instruments simultaneously with one switch. The VAH110 outputs Voltage (for all three battery banks), Amps and Amp-Hours Remaining on the standard NMEA 0183 serial data line at 4800 BAUD. This ASCII information can be used to log performance or repeat the display information at a remote location on the CruzPro RP30 and/or RP110 data repeaters (see www.cruzpro.com/rp30.html and www.cruzpro.com/rp110.html). If NMEA 0183 serial data is not required, then the output terminal can be programmed as an external alarm output pin. A special output wire can be programmed to turn on a charge source such as a generator when the battery gets below a certain amount of charge and to turn the charge source off again at a different programmable level of charge. VAH110 Connection Diagram |
|||||||||||||